Fault Code | Possible Cause | Meaning |
---|---|---|
F.00 | NTC Faults | This means that your Flow NTC cable is defective or broken and needs to be replaced |
F.01 | The Flow NTC cable is defective or broken and needs to be replaced | |
F.10 | - | |
F.11 | ||
F.13 | - | |
F.20 | Over heating problem. Boiler needs to cool down | |
F.22 | Low water in system / overheat | This means that there’s either no water in your system, you have a defective pump or the pump lead is defective |
F.24 | Pump failure or pump blocked | Anything that affects the pump’s ability to circulate water will contribute to the F24 fault code. |
F.28 | No ignition/Ignition problem. No gas! | |
F.29 | Flame loss.( Fan, flue or gas problem ) | Flame or pilot light has gone out – check flue duct or gas supply. |
F.60 | Electrical fault with internal components | Cable loom might have short circuited, gas valve assembly defective or electronic control system issue. |
F.61 | Gas valve control defective | Gas valve control defective( usually comes down to a faulty PCB ) |
F.62 | Defective gas valve closure mechanism | Boiler over heating problem and needs to cool down |
F.63 | EEPROM (Electrically Erasable Programmable Read-Only Memory) error | Electronic faults with internal components. |
F.64 | Electronic system or sensor fault | Flow or back flow NTC has short circuited, or an electronic fault |
F.65 | Electronic system temperature too high | This can happen because of an external heat source or an electrical fault |
F.67 | Electronic fault in the flame system | - |
Fault Code | Possible Cause |
---|---|
F.1 | No gas; Insufficient gas; Incorrect gas valve adjustment; Electrode defect; |
F.4 | No gas; Insufficient gas; Incorrect gas valve adjustment; Electrode defect; |
F.5 | Overheat stat operated; Maximum temperature exceeded; |
F.6 | Your flow NTC has developed a fault. |
F.17 | Check electrical supply / polarity, Check fan. |
F.24 | System fault; Possible external pump failure; |
Fault Code | Possible Cause |
---|---|
F.00, .04, .05, .10, .14, .15 | NTC Faults. |
F.21 | Flame failure fault. |
F.22 | There is insufficient water in your system. |
F.11 | A blockage in the appliance is preventing the system from flowing as it should. |
F.12 | Appliance blocked, low system pressure. |
F.13 | Water deficiency, appliance blocked. |
Fault Code | Possible Cause |
---|---|
S.O | Heating issue, no heat demand |
S.1 | Fan start-up error |
S.2 | Pump flow error |
S.3 | Heating mode error – ignition problem |
S.4 | Heat mode – burner on error |
S.6 | Heating mode – fan overrun error |
S.7 | Heating mode – pump overrun error |
S.8 | Heating remaining cut off for XX amount of time |
S.31 | No heat demand summer operating mode |
S.34 | Heating mode frost protection error |
S.20 | Hot water requirement error |
S.22 | Hot water handling pump flow error |
S.24 | Hot water operation burner is on |
S.85 | Service message quantity of circulation water |
Fault Code | Possible Cause |
---|---|
F.00 / F.0 | Flow temperature sensor de- fective or not connected |
F.01 / F.1 | Return temperature sensor defective or not connected |
F.10 | Flow NTC short circuit |
F.11 | Return NTC short circuit |
F.20 | Safety switch off temperature limiter |
F.22 | Safety switch off low water pressure |
F.23 | Temperature spread too great. Water circulation too low |
F.24 | Temperature increase too fast |
F.25 | Flue gas temperature too high |
F.26 | Error with gas valve – possible no function |
F.27 | Monitoring electrode reports an incorrect flame |
F.28 | Failure during start up – ignition unsuccessful to start |
F.29 | Failure during operation – re-ignition unsuccessful |
F.32 | Fan defective or not connected |
F.49 | eBUS error – possible short circuit |
F.61 | The gas valve assembly cannot be actuated |
F.62 | Error with gas valve – switch off delay |
F.63 | EEPROM error |
F.64 | Electronics, safety-relevant sensor or cable defective |
F.65 | Electronic temperature error could be overheating due to external influences |
F.67 | Electronics flame signal error |
F.68 | Unstable flame signal error air in gas |
F.70 | Invalid device specific number (DSN) |
F.71 | Flow NTC error – flow temperature sensor signal constant value |
F.72 | Flow return NTC error – temperature difference too great |
F.73 | Water pressure sensor reports that the water pressure is too low |
F.74 | Water pressure too high |
F.75 | nsufficient pressure jump de tected when starting the pump |
F.76 | Overheating protection on – primary heat exchanger has responded |
F.77 | No flue non-return flap feed back; condensate pump over flow |
F.78 | Interruption to DHW outlet sensor at external controller |
Interruption to DHW outlet sensor at external controller | Temperature difference between flow and return temperature sensor is too small |
F.84 | Error with flow/return temperature sensor temperature changing error |
F.85 | Flow/return temperature sensors returning incorrect/implausible values |
CONNECTION | Communication fault between the display and the PCB in the electronics box |
Fault Code | Possible Cause |
---|---|
S.00 | Heating mode error – no heat demand |
S.01 | Heating mode fan start-up |
S.02 | Heating mode: Pump pre-run |
S.03 | Heating mode – ignition sequence error |
S.04 | Heating mode – burner ignited |
S.06 | Heating mode – fan overrun error |
S.07 | Heating mode – pump overrun error |
S.08 | Heating remaining cut off time xx minutes |
S.10 | Hot water demand via impeller sensor |
S.11 | DHW mode fan start up error |
S13 | DHW mode ignition error |
S.14 | Hot water demand via fan sensor error |
S.15 | DHW mode pump and fan overrun |
S.16 | DHW mode – fan overrun error |
S.17 | DHW mode – pump overrun error |
S.20 | DHW mode – burner on error |
S.21 | DHW mode – fan start up error |
S.22 | DHW demand – error pump running |
S.22 | DHW demand – error pump running |
S.23 | DHW ignition error |
S.24 | DHW mode – burner error |
S.25 | DHW mode – pump or fan overrun error |
S.26 | DHW mode – fan overrun |
S.27 | DHW mode – pump overrun |
S.28 | Hot water burner anti-cycling time |
S.30 | Room thermostat is blocking heating mode |
S.31 | No heat demand: Summer mode |
S.32 | Waiting period because of fan speed deviation |
S.34 | Heating mode frost protection error |
S.39 | Burner off contact has been triggered this could be because of contact thermostat or condensate pump |
S.40 | Comfort safety mode active |
S.41 | Water pressure > 2.8 bar |
S.42 | Flue non return flap return signal blocks burner operation |
S.46 | Comfort protection mode, flame loss at minimum load |
S.53 | Boiler is in waiting period of modulation f block function due to water shortage |
S.54 | Boiler is in waiting period of operation, blocking function as a result |
S.57 | Waiting period comfort safety mode |
S.58 | Modulation limitation due to noise / wind error |
S.61 | Gas family check unsuccessful |